| Models |
DP1236HE |
DP2463HE |
DP1236HNE |
DP2463HNE |
| Test Volumes (litres) |
1236 |
2463 |
1236 |
2463 |
| Internal chamber dimensions |
|
| Width in mm |
805 |
1610 |
805 |
1610 |
| Depth in mm |
850 |
850 |
850 |
850 |
| Height in mm |
1800 |
1800 |
1800 |
1800 |
|
|
|
|
|
|
|
| |
| Humidity level in % RH |
below 5% |
below 5% |
below 5% |
below 5% |
|
|
|
|
|
|
|
| |
| Number of doors |
3 |
6 |
3 |
6 |
| Number of shelves |
6 |
6 |
6 |
6 |
| Shelf load capacity |
50 kg |
50 kg |
50 kg |
50 kg |
| Electrical services (220/240 volts, single phase) |
13 Amps |
13 Amps |
13 Amps |
13 Amps |
| Compressed Air (oil & water free) |
5-6 Bar |
5-6 Bar |
None |
None |
| Nitrogen gas ( litres / minute) |
None |
None |
10 approx |
10 approx |
|
|
|
| |

Options:
- Cabinet heating up to +40°C with thermostatic control, offering a temperature stability of ±2°C and ±5°C spatial.
- Cooling to +20°C to compensate for high external ambient conditions.
- LRS232/RS422 or Ethernet communications.
- Additional shelves.
- Special storage arrangements e.g. reels or feeders.
- Standby air supply with automatic start up if air loss is detected.
- Data logging of humidity and temperature conditions.
- HEPA filters on air inlet.
|
|

Drystor Product leaflet download
|
|
|